021-58366127

中文EN

Low-temperature Heat System Optimization Technology

Process industries generally define low-temperature heat as heat that is not easily directly utilized, such as process logistics at 80-120 °C and flue gas at 120-200 °C.

Youhua provides overall simulation of waste heat and top-level design technical services for enterprises. The service process is guided by the "three links" theory, following the order of "reduce generation first, then recycle", through the optimization and strengthening of process heat integration to reduce low-temperature heat generation at the source, the use of low-temperature heat in the general area of low-temperature hot water circulation system, and the use of low-temperature heat by green and low-carbon new technologies. According to the heat capacity flow rate matching, temperature matching, combined with the overall process flow and general layout, the top-level design of waste heat utilization is carried out, and the step-by-step implementation promotes the significant reduction of energy consumption of enterprises.

Applications

The technology follows the optimization order of "reducing generation and recycling first", and advances in synergy with the optimization of heat exchange networks, steam power systems, and circulating water systems. The core scenarios include:

Reduce low-temperature heat generation: deep thermal integration, the device uses pinch point technology to optimize the heat exchange network, in-depth recovery of waste heat from process streams such as tower tops and products, and optimization of heat combined heat discharge in the region to improve regional energy utilization efficiency; steam system coordination optimization, on the one hand, low-pressure steam enhanced heat recovery from medium-high-temperature waste heat generation, and on the other hand, the demineralized water/deoxygenated water heat exchange process matches the low-temperature heat cascade utilization; circulating water system coordination optimization, reducing cold utility project costs.

Establish/optimize a hot water circulation system that makes extensive use of low-temperature heat: The low-temperature hot water circulation system consists of a heat source, a heat trap, an auxiliary heater, a aftercooler, an expansion tank, and a circulation pump. The dispersed heat source heat trap is connected to a complete heat integration system using heat medium water as a carrier. The low-temperature thermal waste heat is widely used in hot low-temperature rectification and reboiling, deaerator water heating, storage and transportation system, heating system with heat, waste heat refrigeration system and other units.

Green and low-carbon technology innovates low-temperature heat utilization: heat pump technology, deep thermal integration technology for deaerating oxygen at room temperature, low-temperature evaporation technology, and low-temperature power generation technology.

Results

  • Low-temperature thermal system optimization of a 20-million-ton/year refining and chemical enterprise: saving 3.5MPa steam 10t/h, 1.0MPa steam 2.0t/h, 0.35 MPa steam 3.0t/h, saving electricity 260kW, reducing refining energy consumption 0.567kgoe/t, benefit 23.31 million yuan/year;
  • Local low-temperature thermal system upgrade of an enterprise: Reduce 1.0MPa steam 11.5t/h, circulating water 650t/h, cooling load from 7721kW to 0, benefit 8.694 million yuan/year;
  • A new low-temperature heating system built by a fine chemical company: hot water replaces the heat source of temperature maintenance and reboiler, saving 7t/h of 1.0MPa steam and reducing the power consumption of the cooling system by about 200kW;
  • An ethylene chemical enterprise established an aromatic MTBE thermal self-equilibrium low-temperature heating system, which saves steam by series heating and series heating without steam supplementary heating and circulating water cooling. The full-load operation is about 8.3t/h.

Case studies

Case

Implementation and results

Optimization of low-temperature thermal systems in 20 million tons of refineries

The original design of two sets of low-temperature thermal systems, due to the location of the southern heat trap less, part of the high-temperature logistics degradation output low-temperature heat, low recovery and utilization rate. The hot discharging of wax oil through wax oil hydrofining is carried out to the catalytic unit, diesel oil hydrofining and refining diesel oil gas supply heat, and deaerator water preheating, refrigeration heat exchange station heat trap, jet coal hydrogenation, and continuous reforming heat source are added. Save 3.5MPa steam 10t/h, reduce refining energy consumption 0.567kgoe/t, invest 18 million yuan, benefit 23.31 million yuan/year.

Upgrading and transformation of a local low-temperature thermal system in an enterprise

The crude oil refining catalytic low-temperature thermal system uses parallel heating and parallel heating. The system uses 12.9t/h steam heating, and cools 7721kW with circulating water. The heat exchange process has the potential to be optimized. After transforming to three-stage cascade heating, the temperature of the heating medium water of the outlet device is increased from 120 ℃ to 133.4 ℃, the steam consumption is reduced to 1.4t/h, the subsequent cooling load is reduced to 0kW, the steam is reduced to 11.5t/h, the circulating water is 650t/h, and the investment is 280.2 million yuan, with a benefit of 8.694 million yuan/year.

A new low-temperature thermal system built by an ethylene chemical company

There is no low-temperature thermal system in the factory. The waste heat at the top of the aromatic hydrocarbon rectification tower is air-cooled and water-cooled, and some low-temperature reboilers in the area (<80℃)InLow Voltageis a heat source.Recover the residual heat of the rectification system through a new low-temperature thermal system to replace light hydrocarbon reboiling steam and saveVapor8.3t/h。

Gallery

image

热自平衡低温热系统项目现场(热媒水换热设备)

Tel:021-58366127Email:suna.wang@youhua-opt.com

Copyright:Shanghai Youhua System Integration Technology Co., Ltd.

Links

Scan to follow us

Hotline:

Mr. Wang: 021-58366127/58366330

Address:9F BC, Building 2, No. 428 Yanggao South Road, Pudong, Shanghai (Youyou Century Plaza)

Tel:021-58366127 Email:suna.wang@youhua-opt.com